Product Name : SC APC Simplex Singlemode Fiber Patch Cord 3.0mm
Connector : SC APC
Jacket OD(mm) : 3.0mm
Fiber Mode : 9/125μm
Insertion Loss : ≤0.3dB(IEC Grade C)
Return Loss : SM APC ≥ 60dB
Leave a message to let us serve you better
Fiber Patch Cord are used to provide optical connection for fiber optic electronics. The use of the fiber patch cord provides a quick and easy method for routing fiber patches in data centers, head-ends, cellular hubs and central offices. The fiber patch cord can be used in interconnect or cross-connect path connecting the incoming fibers to the electronic equipment and providing patching within the fiber paths. fiber patch cords include simplex, duplex and Multi-fibers assemblies.
OMC's Fiber Patch Cord are manufactured and tested in compliance with TIA 604 (FOCIS), IEC 61754 and YD/T industry standards. OM1, OM2, OM3, OM4, OM5 or OS2 fiber types to meet the demand of Gigabit Ethernet, 10 Gigabit Ethernet and high speed Fiber Channel. Every termination through rigorous parameter test to ensure the highest in network performance.
Connector’s Standard:
SC: TIA/EIA, FOCIS3, GR-326.NTT-SC IEC61754-4 and JIS C5973.
LC: TIA/EIA, FOCIS10, GR-326 EIA/TIA-604-10, IEC61754-20 and JIS C5973.
FC: EIA /TIA-604-04, FOCIS4, NTT-FC, GR-326. IEC61754-13 and JIS C5973
ST: TIA/EIA, FOCIS2, GR-326. IEC61754-2 and JIS C5973 Etc.
MU: TIA/EIA-604-3A, GR-326.NTT-MU, JIS and IEC.
MTRJ: TIA/EIA, FOCIS12, GR-326. IEC and JIS C5973.
DIN: IEC61754-3
E2000: IEC61754-15
SC/APC Simplex Fiber Patch Cord Specifications
Connector |
SC |
Jacket OD(mm) |
3.0 |
Fiber Mode |
9/125μm, 50/125μm, 62.5/125μm, |
Jacket Color |
SM:White |
Polish |
APC |
Wavelength |
SM:1310/1550nm |
Cable Type |
Simplex |
Jacket Material |
LSZH/PVC/OFNR/OFNP |
Insertion loss |
≤0.3dB(IEC Grade C) |
Insertion loss |
≤0.12dB(IEC Grade B) |
Return loss |
SM APC ≥ 60dB(min) |
Interchangeability &Vibration |
≤0.2dB |
Operating temperature |
-40~75°C |
Storage temperature |
-45~85°C |
Geometric Specification (only for 3D interferometer tested)
Items |
Connector |
PC End-face |
APC End-face |
Radius of Curvature |
SC/FC/ST |
10~25 mm |
5~12 mm |
LC/MU |
7~25 mm |
5~15 mm |
|
Apex Offset |
≤50 um |
||
Fiber Spherical Height |
+/- 100 nm |
||
Angular Offset |
------ |
8°± 0.5° |
End-face Quality (SM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 25 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
25 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
End-face Quality (MM)
Zone |
Range (μm) |
Scratches |
Defects |
Reference |
A: Core |
0 to 65 |
None |
None |
IEC 61300-3-35:2015 |
B: Cladding |
65 to 115 |
None |
None |
|
C: Adhesive |
115 to 135 |
None |
None |
|
D: Contact |
135 to 250 |
None |
None |
|
E: Rest of ferrule |
None |
None |
Length Tolerance
Overall Length(L)(m) |
length of tolerance(cm) |
0<L<1 |
+5/-0 |
1<L<10 |
+10/-0 |
10<L<40 |
+15/-0 |
40<L |
+0.5% x L/-0 |