Product Name : Optical Power Meter
Model : FHP2
Connector : Interchangeable FC/PC, SC/PC
Calibrated Wavelength : 850/1300/1310/1490/1550/1625nm
Power Supply : 2pcs*Ni-MH AA (2500mAh); USB cable
Operating Temperature : -10~+50℃
Dimension : 160mmL*76mmW*45mmH
Weight : 270g
FHP2 Series Optical Power Meter is the advanced version of OPM series. It is more functional and intelligent.Under the situation of laboratory, LANs, WANs and CATV as well as long distance optical network, Optical Power Meters,together with OMC's Stabilized Optical Laser Sources, can be used to identify optical fiber, measure optical attenuation,verify continuity an evaluate fiber link transmission quality.
Auto-wavelengths Recognition:
FHS2D02 Optical Laser Source can transmit with a wavelength identification digital encrypted protocol, enabling FHP2 Series Optical Power Meter to automatically switch to the proper calibration wavelength. This feature reduces the need for communication between the two technicians and decreases the possibility of making mistakes.
Referencing Function:
Signal encrypting can also give the receiving end information on the power to be used as reference, helping ensure efficient referencing, even when the two units are far apart.
Computer Supported:
Memory capacity of 1,000 data items; enables data transfer to a PC via USB connection.With the software, the datasheet can be saved as excel or txt, and print out directly.
Testing Range:
Maximum testing range up to 150km (when using OMC’s FHS2D02 Optical Laser Source with OMC’s FHP2A04 Optical Power Meter).
FHP2 Optical Power Meter Specifications:
Model |
FHP-2A04 |
FHP-2B04 |
Calibrated Wavelength |
850/1300/1310/1490/1550/1625nm |
|
Detector Type |
InGaAs |
|
Accuracy |
±0.2db±1nW |
±0.2db±10nW |
Resolution |
0.01dB |
|
Linearity |
±5% |
|
Auto Power-off |
Yes |
|
Back-light |
Yes |
|
Reference Value |
Yes |
|
Connector |
Interchangeable FC/PC, SC/PC |
|
Measuring Range |
-70 to +10dBm @1550nm |
-50 to +26dBm @1550nm |
USB Interface |
Yes |
|
Data Storage |
Yes |
|
Wavelength Recognition |
Yes (≥-40dBm) |
Yes (≥-20dBm) |
Tone Detection |
270, 1k, 2kHz (≥-40dBm) |
270, 1k, 2kHz (≥-20dBm) |
Operating Temperature |
-10 to +50℃ |
|
Storage Temperature |
-20 to +70℃ |
|
Power supply |
2pcs*Ni-MH AA (2500mAh); USB cable |
|
Dimension |
160L*76W*45mmH |
|
Net Weight |
270g |
|
Standard Accessories: |
||
FC/PC adapter, SC/PC adapter, 2*AA rechargeable batteries, USB cable, test report, carrying bag, CD software, user manual |
||
Optional Accessories: |
||
Interchangeable ST adapter ;male FC to female LC adapter for LC connector |